Move/3500: Configuring device settings

Modified on Thu, 4 Jun at 6:30 PM

This article explains how to configure a Move/3500 device. 

  • Select the white Menu button on the device keypad (the one with the dot):
01.png
  • In Huvudmeny, select Adminmeny (or press nr. 8 on keypad):
02.jpg
  • Swipe the merchant card:
03.jpg
  • In Adminmeny, select Inställningar (or press nr. 6 on keypad):
04.jpg
  • Select Ändra (or press nr. 1 on keypad):
05.jpg
  • Select Funktion and make sure all the settings are correct:
06.jpg
  • 1 – FUNKTION
    • Terminal ID: XXX
    • Beloppsläge = Kronor (Öre)
    • S&F = Ja (Nej)
    • Serv Första = Nej (Ja)
    • Infofält = Ingen info (Ocr, Info text, Kassör ID)
    • Ljud = Vid fel (Alltid, Inget)
    • PIN knappljud = Alltid (Inget)
    • Alltid Kopia = Nej (Ja)
    • Dublettkontr. = Nej (Ja)
    • Language = Swedish
    • Dricks = Totalbelopp (NEJ, Extrabelopp)
    • Ändra kassör = Utan kassör (Dagsavslut, Z-total, Alltid, O-Rapport)
    • Moms = Fast moms (Ingen moms, Ändra moms)
    • Momssats = 0,00
    • Automatiskt av = Aldrig (Efter 1 timme, Efter 2 timmar)
    • Reservför. Språk = English
    • Bakgrundsljus = Auto (Alltid)
    • Chip info text = Chip uppåt (Chip mot dig, Chip ned)
    • Kundkvitto = Alltid (Vid behov)
    • IFR Priority = Domestic (International, None)
    • Reboot Time = 04:00
  • Select Kommunikation and make sure all the settings are correct:
07.jpg
  • 2 - KOMMUNIKATION
    • Komm. typ = WIFI (Ethernet - not used, BT Android - not used, VIA ECR - not used, GPRS - not used)
    • DHCP = DHCP
    • HOST IP address =91.102.24.142
    • HOST IP port = 9670
  • Select Kassa and make sure all the settings are correct:
08.jpg
    • 3 – KASSA
      • ECR = JA (NEJ - not used) // Should always be Ja.
      • Komm.Typ = IP WIFI (BT Android - not used, IP ETHERNET - not used, USB slave - not used) 
      • ECR/TLS = NEJ (JA - not used)
      • ECR IP ADRESS = x.x.x.x 
        // If setting up for p@t: Enter the IP address of the POS running Baxi Agent.
        // If setting up for Baxi: Enter the IP address of the POS sending transactions to the terminal. 
      • ECR IP Port = 6001, 6002.. (Baxi) or 6009 (BaxiAgent) 
        // If setting up for p@t: Always use 6009 to connect to Baxi Agent. 
        // If setting up for Baxi: Use 6001 or 6002, 6003 etc., in case there are several terminals configured on the POS device, 1 port per terminal
      • Kortinfo = Aldrig (Alltid, Efter belopp)
      • Kvittohuvud/-fot = Nej (Ja)
  • Press the red button (Stop) several times until the device restarts.